Origin: Guangdong, China (Mainland)
Brand Name:Unionwell
Model: G5W11-A001U
Terminal type: external wire
Contact form: Double pole double throw - normally open
Operating handle type: standard straight handle
Safety certification: All products have obtained major global safety certifications
Company quality assurance system: ISO9001, IATF16949 and ISO14001
Applications: Household appliances, electronic equipment, automation equipment, automotive electronics, agricultural machinery, office equipment, etc.
Waterproof and dustproof (IP67)
Compact structure, small movement stroke, high sensitivity
Global safety certification
Long life, high precision and high reliability
Various handles available
Widely used in automotive electronics, home appliances and industrial control, etc.
Maximum ENEC/UL certified current up to 10A
Rating | W1 | ENEC: 0.1A 48VDC, 0.1A 125/250VAC, 40T85, 5E4, u UL: 0.1A 48VDC, 0.1A 125/250VAC, T85 |
W2 | ENEC: 5A 125/250VAC, 5A, 30VDC, 40T85, 5E4, u UL: 5A 125/250VAC, T85 | |
W3 | ENEC:10(2)A 125/250VAC, 0.5A 125VDC, 0.25A 250VDC,40T85,u,2E4 UL:10.1A 1/10HP 125/250VAC,0.5A 125VDC, 0.25A 250VDC, T85 | |
Operating frequency | electric | 10~30 times/min |
mechanical | 60 times/min | |
Contact resistance | Terminal type | 50mΩMax |
Lead wire type | 100mΩ Max(Depends on the length of the wire) | |
Insulation resistance | at 500VDC,100MΩ Min. | |
Dielectric strength | Between terminals of the same level | AC 1000V 50-60Hz 1min |
Terminal housing | AC 1500V 50-60Hz 1min | |
Storage temperature | -40°C~+85°C | |
Storage humidity | 85%RH Max | |
Protective structure | Terminal type | IEC IP67(Terminal not included) |
Lead wire type | IEC IP67 | |
Protection level against electric shock | Class I | |
PTI | 250 | |
life | electric | 2E4~10E4 cycles (depends on P/NS) |
mechanical | over 1000,000cycles(60cycles/min) | |
Unit weight | Approx.7g (terminal type, without handle) |